Skip to content
Fort Lauderdale, FL · Licensed across FloridaMon–Fri 10:00 AM – 6:00 PM · (954) 807-3208
Romco IndustrialCall

What decides the cost · Fire Protection

Designed for What Is Actually Stored

The sprinkler system is determined by what is stored and how high it is stacked, which is information a speculative developer does not have.

The geotechnical report, the intended clear height and the likely tenant profile. Those three tell us more than a full set of drawings.

The slab

The one element a tenant judges on, and cannot fix

Self-perform

Dewatering and deep foundations in house

Commodity

Fire protection designed to what is actually stored

Licensed

General contractor, licensed in the state of Florida

The tenant decides a system built before they existed

Commodity classification and storage arrangement drive the design. Plastics and aerosols demand far more than cardboard boxes. A building sprinklered for a modest assumption and then leased to a tenant storing something more demanding needs a system upgrade — in an occupied building, at the tenant's or the landlord's expense, and always as an argument.

What drives the design

  • Commodity classification of what will actually be stored.
  • Storage height and arrangement, including rack configuration.
  • Whether in-rack sprinklers are needed, which changes everything.
  • Available water supply, and whether a pump and tank are required.
  • Clear height, which the sprinkler design has to reach.

How we handle it

  1. 01Design to a realistic tenant profile, discussed openly.
  2. 02Identify what the design will and will not cover, in writing.
  3. 03Coordinate sprinkler layout with racking and clear height.
  4. 04Establish water supply adequacy before design is fixed.
  5. 05Hand over documentation a future tenant can be assessed against.

Write down what commodity class the building is designed for and give it to the leasing team. It lets them qualify tenants at inquiry rather than discovering a mismatch after a lease is signed.

Said plainly

Where we stop

We cannot design a system that suits every possible tenant. Designing for the most demanding case is expensive and designing for the least is a future upgrade, and choosing between them is the developer's call — made with the numbers, not by default.

FAQ

Common questions

What decides the sprinkler design?
Commodity classification and storage height. Both come from the tenant.
Can it be upgraded later?
Yes, in an occupied building, expensively, and usually as an argument about who pays.
What should we tell leasing?
The commodity class the building is designed for, so they can qualify tenants at inquiry.
Do we need a pump and tank?
It depends on the available water supply. Establish it before design is fixed.

Next step

Find out what is actually wrong with it.

An inspection, photographs of what we found, and a written scope. If the honest answer is that it can wait another season, that is the answer you will get.